Appendix DGlossary

The acronyms and terms used in the tutorial, with the chapter that introduces each.

Term Meaning Chapter
AAF Anti-aliasing filter: removes what would fold into the band when sampled 11, 13
Active electrode An electrode with a buffer or amplifier at the skin, to lower the impedance its lead presents 12
AFE Analog front-end: everything between the electrodes and the converter 1
Applied part (B, BF, CF) The IEC 60601 classes of patient connection; CF (cardiac) has the strictest current limits 4
Bootstrapped switch A sampling switch whose gate rides on the input, so its on-resistance does not depend on the input 15
CCIA Capacitively coupled instrumentation amplifier: gain set by input and feedback capacitors 7
CDAC Capacitive digital-to-analog converter, the core of a SAR converter 17
Chopping Modulating the signal up to a higher frequency before an amplifier and back after it, to remove offset and 1/f noise 9
CIC, CoI Cascaded integrator–comb and cascade-of-integrators decimation filters 20, 23
CMRR Common-mode rejection ratio: differential gain over common-mode gain 4, 7
Coherent sampling Choosing a test tone that completes a whole number of cycles in the record, so the FFT needs no window 22
Cole model A tissue-impedance model with a constant-phase dispersion between a low- and a high-frequency resistance 28
DNL, INL Differential and integral nonlinearity: errors of each code step and of the transfer curve, in LSB 14
DRL, RLD Driven right leg, right-leg drive: feedback that drives the body’s common mode through a third electrode 12
DSL DC servo loop: an integrator that removes the electrode offset from the amplifier 10
Driven shield, guard A shield or guard held at the signal’s own voltage, so its capacitance draws no current 4, 12
ΔΣ (delta-sigma) An oversampling converter that shapes its quantisation noise out of the band 19
ECG, EEG, EMG, EOG Electro-cardio-, encephalo-, myo- and oculography: heart, brain, muscle and eye potentials 2
ECoG, LFP Electrocorticography and local field potentials, recorded on or in the brain 2
EIS, bioZ Electrical impedance spectroscopy, bioimpedance: measuring tissue impedance with a small current 28
ENOB Effective number of bits: (SNDR − 1.76 dB)/6.02 13
ExG Any of the surface biopotentials (ECG, EEG, EMG, EOG) 2
FoM (Walden, Schreier) Converter figures of merit: energy per conversion step, and SNDR plus bandwidth over power 14
gm/ID Transconductance efficiency, the design variable of the gm/ID method 5
Incremental ΔΣ A ΔΣ converter reset before each conversion, so it behaves like a Nyquist converter with high resolution 19, 20
IQ demodulation Multiplying by in-phase and quadrature references to recover amplitude and phase 28
kT/C The thermal noise frozen on a capacitor when a switch opens 15
LDO Low-dropout regulator 27
LNA Low-noise amplifier, the first gain stage 8
Moderate / weak inversion MOSFET operation near or below threshold, where gm/ID is highest 5
NEF, PEF Noise and power efficiency factors: an amplifier’s noise for its current, relative to one bipolar transistor 6
NTF, STF Noise and signal transfer functions of a ΔΣ loop 19
OSR Oversampling ratio: sample rate over twice the signal bandwidth 13
OTA Operational transconductance amplifier 8
PGA Programmable-gain amplifier 11
Pseudo-resistor Diode-connected MOSFETs far below threshold, used as teraohm resistors 8
PSRR Power-supply rejection ratio 27
RF rectification Radio-frequency interference turned into a low-frequency error by a nonlinear input stage 12
SAR Successive-approximation register converter: a binary search with a DAC and a comparator 18
SFDR, SNDR, THD Spurious-free dynamic range, signal to noise and distortion, total harmonic distortion 14
SQNR Signal-to-quantisation-noise ratio: 6.02N + 1.76 dB for an ideal N-bit converter 13
StrongARM A clocked latch comparator with no static current 16
Tetrapolar Impedance measurement with separate current and voltage electrodes 28
Zcm Common-mode input impedance of the front-end 4